Processing complete – nothing needs checking
Project details
Client, designer, site
Plot
Zoning rules and plot figures
Planning rules
Values
Rooms
Rooms, floor areas, floor finishes
| Name | Area (m²) | Floor covering | Delete row |
|---|---|---|---|
| Total net floor area: | 117.91 | ||
Doors & windows
External and internal doors, windows, lintels
External doors and windows
| Name | Size (cm) | Area (m²) | Qty | Total (m²) | Wall / lintel | Delete row |
|---|---|---|---|---|---|---|
| 2.25 | 11.25 | 15 pcs | ||||
| 1.80 | 5.40 | 9 pcs | ||||
| 0.36 | 0.72 | 6 pcs | ||||
| 5.28 | 5.28 | 3 pcs | ||||
| 2.10 | 2.10 | 3 pcs | ||||
| Total | 12 | 24.75 | ||||
Internal doors
| Name | Size (cm) | Area (m²) | Qty | Total (m²) | Wall / lintel | Delete row |
|---|---|---|---|---|---|---|
| 1.89 | 11.34 | 6 pcs | ||||
| 1.58 | 4.74 | 3 pcs | ||||
| Total | 9 | 16.08 | ||||
Walls & parameters
Perimeter, facade height, walls, ceiling height, roof pitch
Values used for the facade, external wall, loft floor and roof calculations.
| Thickness (cm) | Length (m) | Material | Delete row |
|---|---|---|---|
| Total | 43.0 | ||
Quantities
By module – switched-off modules stay out of the PDF
Net floor area: 117.91 m²
Use the switches on the cards to choose which modules go into the report.
Screed / floor slab
Pumped screed (5 cm, M20), edge insulation strip and welded mesh, based on the net area of the indoor rooms and the garage.
In the PDF← Source: Net area of the indoor rooms and the garage (automatic, from the room schedule)
Screed area: 117.91 m² · Layer thickness: 5 cm (M20 pumped screed)
Item Quantity Unit Screed area 117.91 m² Concrete (5 cm) 5.9 m³ Edge insulation strip 132 lm Reinforcing mesh+15% overlap 136 m² Impact-resistant floor insulation
Impact-resistant insulation and PE membrane based on the net area of the indoor rooms (excluding terraces, garages, balconies and other outdoor or unheated spaces), with allowance.
In the PDF← Source: Net area of the indoor rooms (excluding terrace, garage, balcony, porch, carport, loggia, boiler room and basement)
Indoor net area: 117.91 m²
Item Quantity Unit Impact-resistant insulation+10% 130 m² PE membrane+12% 133 m² Loft floor insulation
Mineral wool insulation and vapour barrier based on the footprint of the largest storey, with allowance; no loft floor where the attic is inhabited.
In the PDF← Source: Footprint of the largest storey (Walls & parameters section)
Footprint: 144.00 m²
Item Quantity Unit Mineral wool+8% 156 m² Vapour barrier+12% 162 m² Plasterboard suspended ceiling
Per-room CD/UD framing, direct hangers and plasterboard — moisture-resistant board in wet rooms.
In the PDF← Source: Net area of the indoor rooms (excluding terrace, garage, balcony, porch, carport, loggia, boiler room and basement)
Item Quantity Unit Plasterboard+10% 63 pcs Direct hanger 359 pcs Screws 1,814 pcs Jointing compound 51 kg External wall insulation
Facade area (perimeter × height, openings deducted): EPS, adhesive, mesh, plugs, starter profile.
In the PDF← Source: Building perimeter + facade height (Walls & parameters section)
Perimeter: 49.2 m / Height: 3.2 m
Item Quantity Unit EPS board+10% 292 pcs Adhesive+5% 697 kg Glass-fibre mesh+10% 146 m² Fixing plugs+5% 836 pcs Starter profile+5% 52 lm Corner beadwindow/door reveals, +5% 54 lm Render primer0.25 kg/m² 35 kg Finish render (top coat)scratch finish 1.5 mm, 2.5 kg/m² 349 kg Masonry / blockwork
Brick, mortar, AAC or plasterboard partitions, lintels and ring beam, based on external/internal wall area.
In the PDFItem Quantity Unit External brick+5% 6,967 pcs External mortar 10,589 l Internal brickNF brick, +5% 2,412 pcs Internal mortar+5% 3,304 l AAC partition block+5% 0 pcs AAC adhesive~3.5 kg/m², +5% 0 kg Partition plasterboardboth sides, +10% 0 pcs CW stud600 mm centres, +5% 0 lm UW track+5% 0 lm Partition screws+10% 0 pcs Partition jointing compound+7% 0 kg Mineral wool infill+5% 0 m² Lintel (PTH-A10)ceil(wall thickness/13) side by side 45 pcs Lintel length (PTH-A10)opening + 25 cm bearing 66 lm Lintel (AAC)over openings in AAC partitions 0 pcs Lintel length (AAC)opening + 25 cm bearing 0 lm Ring beam concretewall thickness × 25 cm, along the perimeter 4.7 m³ Ring beam reinforcement~100 kg/m³ 468 kg Ring beam formwork 25 m² Plastering
Cement plaster based on internal wall and ceiling area plus the external facade — 1.0 cm internal, 1.5 cm external.
In the PDFItem Quantity Unit Internal plasterfrom room perimeter, openings deducted 306 m² Internal cementwall + ceiling, 1.0 cm, 14 kg/m², +5% 6,229 kg External render 133 m² External cement 2,926 kg Painting / skim coat
Wall and ceiling area to be painted: primer, 2 coats of paint and skim (wall 10 m²/l, ceiling 8 m²/l).
In the PDFItem Quantity Unit Wall to painttiled area deducted 263.11 m² Ceiling 117.91 m² Primer – wall10 m²/l 27 l Primer – ceiling8 m²/l 15 l Paint – wall2 coats, 10 m²/l 53 l Paint – ceiling2 coats, 8 m²/l 30 l Skim – wall0.4 kg/m² (smoothing) 106 kg Skim – ceiling0.5 kg/m² 59 kg Full skim coat (option)1.8 kg/m² – INSTEAD OF the smoothing skim, not in addition 686 kg Tiling / flooring
Floor covering by type (hard/soft) plus tile adhesive, grout and skirting — with cutting allowance.
In the PDF← Source: Floor covering type (automatic, from the room schedule)
Item Quantity Unit Hard flooring 35.2 m² Floor tile (30×30 cm)+10% 430 pcs Parquet / laminate+5% 87 m² Wall tile areawet rooms, +10% 46.98 m² Wall tile (25×40 cm) 470 pcs Tile adhesive4 kg/m² 328 kg Grout 41 kg Skirting boardperimeter of soft flooring 77 lm Roofing
Tiles, battens, underlay and rafters based on the sloped roof area, plus gutter and downpipe.
In the PDFItem Quantity Unit Roof area+10% eaves overhang 193.37 m² Roof tiles10 pcs/m², +10% cutting allowance 2,128 pcs Ridge tilesridge, ~3 pcs/lm 47 pcs Vent tileseaves course 20 pcs Rafters 165 lm Battens 614 lm Counter battensalong the rafters 165 lm Roofing underlay+15% overlap 223 m² Gutter2× building length, +5% 26 lm Downpipe outlet~1 per 10 lm 3 pcs Downpipe 12 lm